- Motor and drive troubleshooting kit includes Fluke 1587 manual and auto-ranging digital insulation multimeter, Fluke i400 current clamp, and a Fluke 9040 phase rotation indicator True RMS meter provides accurate readings when measuring linear or nonlinear loads where the current or voltage has an undistorted or distorted waveform Fluke i400 current clamp measures AC current without breaking the circuit Fluke 9040 phase rotation indicators checks the rotation of three-phase motors Meets IEC safety standards IEC/EN 61010 for Category III and Category IV installations, and Degree 2.
The Fluke 1587 MDT advanced insulation and motor drive
troubleshooting kit is designed for troubleshooting and
preventive maintenance applications including three-phase motors,
cables, switch gear, and in applications where testing is
required without the need to break the circuit. The kit includes
the Fluke 1587 digital insulation multimeter, Fluke i400 current
clamp, and Fluke 9040 phase rotation indicator. The Fluke 1587
digital insulation multimeter (also known as a multitester) is a
true RMS, auto- and manual-ranging meter insulation resistance,
current, voltage, and resistance for testing line insulation in
telecommunications applications. The insulation test voltage
settings of 50V, 100V measure resistance from 0.01 to 100
megohms. The meter also measures capacitance, frequency, and
resistance. Temperature is measured using a K-type thermocouple
(included). A diode test detects correct functioning of a
circuit's diodes. A low-pass filter provides accurate AC voltage
and AC frequency measurements on inverters and variable-frequency
motor drives by blocking unwanted voltages. Live circuit
detection increases user safety by preventing insulation tests
when voltages exceed 30V, and auto-discharge of capacitive
voltage increases user protection. An audible continuity sensor
confirms a circuit conducts electricity. The LCD is backlit for
readability in low light. A hold function freezes the reading on
the display. An alarm sounds when the test leads are connected to
the wrong jack for the measurement being taken. The unit
automatically turns off after 20 minutes of nonuse to conserve
battery life or can be disabled for extended readings, and a
low-battery indicator signals when the meter's batteries need to
be replaced. The meter included a set of detachable test leads, a
remote probe, alligator clips, a hard case, and instructions.
This true RMS (root mean square) insulation multimeter provides
accurate readings when measuring linear loads, such as standard
induction motors and incandescent lights, where the current or
voltage has an undistorted waveform, or nonlinear loads, such as
electronic devices or motors, where the current or voltage has a
distorted waveform. When turned on, the meter is in auto-ranging
mode and automatically selects the correct operating range for
the property being measured. It can be switched to manual-ranging
mode, which allows the operator to choose the appropriate
operating range. The display has a 6,000-count resolution,
meaning it can display up to 5,999 units (3-3/4 digits) before
the operating range needs to be changed. It meets International
Electrotechnical Commission (IEC) safety standard 61010 and is
certified Category III installations up to 1000V, which covers
items used with enclosed building circuit installations (such as
service panel parts, branch circuits, and fixed installations
that are connected directly to a building's AC power supply),
Category IV installations up to 600V, which covers equipment at
the origin of the installation (such as electricity meters and
primary over-current protection equipment), and Degree
2 for indoor use.
The Fluke i400 current clamp is a single-range 400-amp AC
current clamp designed to extend the measuring capability of AC
current meters to 400 amp. It has a 1 to 400 amp continuous
current range and outputs 1 milliamp/amp. The clamp uses 4mm
safety shrouded banana plugs. It meets International
Electrotechnical Commission (IEC) safety standard 61010 and is
certified Category III installations up to 1000V, which covers
items used with enclosed building circuit installations (such as
service panel parts, branch circuits, and fixed installations
that are connected directly to a building's AC power supply),
Category IV installations up to 600V, which covers equipment at
the origin of the installation (such as electricity meters and
primary over-current protection equipment), and Degree
2 for indoor use.
The Fluke 9040 phase rotation indicator is designed to measure
phase rotation where three-phase supplies are used to feed
motors, drives, and electrical systems in commercial and
industrial applications. The LCD displays field rotation and
direction to determine correct connections. The indicator has a
voltage range of 40 to 700V, a frequency range of 5Hz to 20kHz,
and a continuous operating timer. The included test probes have a
variable clamping range for safe contact. It meets International
Electrotechnical Commission (IEC) safety standard 61010 and is
certified Category III installations up to 600V, which covers
items used with enclosed building circuit installations (such as
service panel parts, branch circuits, and fixed installations
that are connected directly to a building's AC power supply),
Category IV installations up to 300V, which covers equipment at
the origin of the installation (such as electricity meters and
primary over-current protection equipment), and Degree
2 for indoor use.
Specifications
--------------
Fluke 1587 Insulation Multimeter Specifications
Insulation test voltages 50V, 100V, 250V, 500V, 1000VInsulation
measurement range 0.01 megaohms to 2 gigohmsMaximum AC and DC
voltage measurement 1000VMaximum AC and DC current measured 60
milliampsResistance 0.1 ohms to 50 megaohmsMaximum frequency
99.99kHzTemperature probe and range K-type thermocouple -40 to
+537 degrees C/-40 to +998 degrees FMaximum capacitance 9999
microfaradsPower supply 4 AA batteries (NEDA 15A or IEC
LR6)Safety ratings Ingress Protection certified IP40; European
Conformity (CE); Underwriter's Laboratory (UL) 61010-1; ANSI/ISA
S82.01-2004; Canadian Standards Association (CAN/CSA) C22.2 No.
1010.1:2004; International Electrotechnical Commission (IEC)
safety standards IEC61557-1; IEC61557-2; IEC 61010-1:1002, IEC
61010.1-04, and IEC/EN 61010-1, 2nd edition for Category III
installations up to 1000V and Category IV installations up to
600V, and Degree 2 Weight 1.2lb./550gDimensions 1.97 x
3.94 x 8.00 inches/5.0 x 10.0 x 20.3cm (H x W x D)Fluke i400
Current Clamp
Nominal current range 400 ampContinuous current range (Duty
cycle) 1 to 400 ampLowest measurable current 1 ampUseable
frequency 5Hz to 20kHzOutput levels 1 milliamp/amp (mA/A)Maximum
voltage 1000VAC RMS from earth to ground, in compliance with
EN61010Maximum conductor diameter 32mm/1.25 inchesMaximum
conductor size (busbar) 750 MCMSafety ratings European Conformity
(CE); Underwriter's Laboratory (UL) 61010-1; ANSI/ISA
S82.01-2004; Canadian Standards Association (CAN/CSA) C22.2 No.
1010.1:2004; International Electrotechnical Commission (IEC)
safety standards EN 61326-1, IEC/EN 61010-1, 2nd edition for
Category III installations up to 1000V and Category IV
installations up to 600V, and Degree 2 Weight
114gDimensions 150 x 70 x 30mm (H x W x D)Fluke 9040 Phase
Rotation Indicator Specifications
Voltage range40 to 700VFrequency range15 to 400HzOperating
timerContinuousPower supplyFrom unit under testSafety
ratingsIngress Protection certified IP40; International
Electrotechnical Commission (IEC) safety standards IEC/EN 61557-7
and IEC/EN 61010-1 for Category III installations up to 600V and
Category IV installations up to 300V, and Degree
2Weight200gDimensions124 x 61 x 27mm (H x W xD)
H is height, the vertical distance from the lowest to highest
point; W is width, the horizontal distance from left to right; D
is depth, the horizontal distance from front to back.
Multimeters are electrical test meters that measure multiple
properties of an electrical circuit, such as current, voltage,
resistance, capacitance, and continuity. Available in handheld or
benchtop models, multimeters diagnose electrical problems in
electrical equipment, wiring, and power supplies. A variety of
probes, clamps, and leads can be used to connect the meter to a
circuit or device. Multimeters display information either in
analog or digital form. Factors that influence meter choice
include the electrical properties to be measured, the anticipated
range of results, and the desired level of protection against
transient voltage. Safety ratings are based on International
Electrotechnical Commission (IEC) standards for low-voltage test
equipment. IEC 61010 delineates four overvoltage installation
categories. In general, a meter with a category IV rating will
provide more protection against transient voltages than a meter
with a lower category rating.
Fluke Corporation manufactures electrical testing tools and
software for industrial and commercial applications. The company,
founded in 1948, is headquartered in Everett, WA.
What's in the Box?
------------------
* Fluke 1587 Insulation Multimeter
* Fluke i400 current clamp
* Fluke 9040 phase rotation indicator
* K-type thermocouple
* Remote probe
* Alligator clips
* Test leads (red and black)
* (3) Self-retaining phase rotation test probes
* (4) AA alkaline batteries
* Hard case
* Instructions